Strany 2

UPC Start Setup End Setup ,ZZ, ,ZZ, UPC-A Settings: UPC-A leading zero check digit transmission UPC-A, no leading zero,

Strany 3 - Table of Contents

EAN Start Setup End Setup ,ZZ, ,ZZ, EAN Settings: EAN-13 and EAN-8 Check Digit Transmission not transmit EAN-13 check di

Strany 4 - Introduction

EAN Supplement Settings: EAN Symbologies Exclusive Enable Disable EAN no supplement (default enable) ,J4, ,R4, ,X4E, EAN with 2-digit supplement ,J5,

Strany 5 - Installation

Code 39 Start Setup End Setup ,ZZ, ,ZZ, Code 39 Settings: Code 39 Exclusive Enable Disable Code 39 Enable/Disable (defau

Strany 6 - Configuration

Codabar Start Setup End Setup ,ZZ, ,ZZ, Codabar Settings: Codabar Exclusive Enable Disable Codabar Enable/Disable (defau

Strany 7 - Setup Codes

Codabar Settings Continued: Codabar Minimum Digit minimum data = one character ,HC, minimum data = three characters ,HB, minimum data = five charac

Strany 8

Code 128 Start Setup End Setup ,ZZ, ,ZZ, Code 128 Settings: Codabar Exclusive Enable Disable Code 128 Enable/Disable (de

Strany 9 - Set to factory default:

Code 93 Start Setup End Setup ,ZZ, ,ZZ, Code 93 Settings: Symbology Exclusive Enable Disable Code 93 (default enable) ,

Strany 10 - ,ZZ, ,ZZ

Code 11 Start Setup End Setup ,ZZ, ,ZZ, Code 11 Settings: Symbology Exclusive Enable Disable Code 11 (default disable)

Strany 11

2 of 5 and S-Code Start Setup End Setup ,ZZ, ,ZZ, 2 of 5 and S-Code Settings: Symbology Exclusive Enable Disable Indust

Strany 12 - EAN-8 Supplement Settings:

Warning: This equipment generates, uses and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual

Strany 13 - Code 39

MSI / Plessey Start Setup End Setup ,ZZ, ,ZZ, MSI / Plessey Settings: Symbology Exclusive Enable Disable MSI / Plessey

Strany 14 - Codabar

UK / Plessey Start Setup End Setup ,ZZ, ,ZZ, UK / Plessey Settings: Symbology Exclusive Enable Disable UK / Plessey (de

Strany 15 - Codabar Settings Continued:

POSTNET Start Setup End Setup ,ZZ, ,ZZ, POSTNET Settings: Symbology Exclusive Enable Disable POSTNET (default disable)

Strany 16 - Code 128

Intelligent Mail Bar Code Start Setup End Setup ,ZZ, ,ZZ, Intelligent Mail Bar Code Settings: Symbology Exclusive Enabl

Strany 17 - Code 93

GS1 DataBar Start Setup End Setup ,ZZ, ,ZZ, GS1 DataBar Settings: Symbology Exclusive Enable Disable GS1 DataBar Omnidi

Strany 18 - Code 11

Korean Postal Authority Start Setup End Setup ,ZZ, ,ZZ, Korean Postal Authority Code Settings: Symbology Exclusive Enab

Strany 19 - 2 of 5 and S-Code

IATA Start Setup End Setup ,ZZ, ,ZZ, IATA Settings: Symbology Exclusive Enable Disable IATA (default enable) ,A4, ,B4,

Strany 20 - MSI / Plessey

Tri-Optic Start Setup End Setup ,ZZ, ,ZZ, Tri-Optic Settings: Symbology Exclusive Enable Disable Tri-Optic (default ena

Strany 21 - UK / Plessey

Telepen Start Setup End Setup ,ZZ, ,ZZ, Telepen Settings: Symbology Exclusive Enable Disable Telepen (default enable) ,

Strany 22 - POSTNET

JPN (Customer Bar Code) Start Setup End Setup ,ZZ, ,ZZ, JPN Settings: Symbology Exclusive Enable Disable JPN (default d

Strany 23 - Intelligent Mail Bar Code

Table of Contents Introduction Chapter 1 Installation ...

Strany 24 - GS1 DataBar

PDF417 Start Setup End Setup ,ZZ, ,ZZ, PDF417 Settings: Symbology Exclusive Enable Disable PDF417 (default enable) ,BC3

Strany 25 - Korean Postal Authority

Micro PDF417 Start Setup End Setup ,ZZ, ,ZZ, Micro PDF417 Settings: Symbology Exclusive Enable Disable Micro PDF417 (de

Strany 26

Maxi Code Start Setup End Setup ,ZZ, ,ZZ, Maxi Code Settings: Symbology Exclusive Enable Disable Maxi Code (default ena

Strany 27 - Tri-Optic

QR Code Start Setup End Setup ,ZZ, ,ZZ, QR Code Settings: Symbology Exclusive Enable Disable QR Code (default enable) ,

Strany 28 - Telepen

Micro QR Start Setup End Setup ,ZZ, ,ZZ, Micro QR Settings: Symbology Exclusive Enable Disable Micro QR (default enable

Strany 29 - JPN (Customer Bar Code)

Aztec Code Start Setup End Setup ,ZZ, ,ZZ, Aztec Code Settings: Symbology Exclusive Enable Disable Aztec Code (default

Strany 30

Aztec Runes Start Setup End Setup ,ZZ, ,ZZ, Aztec Runes Settings: Symbology Exclusive Enable Disable Aztec Runes (defau

Strany 31 - Micro PDF417

Data Matrix Start Setup End Setup ,ZZ, ,ZZ, Data Matrix Settings: Symbology Exclusive Enable Disable Data Matrix (ECC 2

Strany 32 - Maxi Code

Codablock F Start Setup End Setup ,ZZ, ,ZZ, Codablock F Settings: Symbology Exclusive Enable Disable Codablock F (defau

Strany 33 - QR Code

Chinese Sensible Code Start Setup End Setup ,ZZ, ,ZZ, Chinese Sensible Code Settings: Symbology Exclusive Enable Disabl

Strany 34 - Micro QR

Introduction Worth Data's 520-2D is a versatile bar code reader that can attach to any PC or Mac USB port. It can also be used as an external re

Strany 35 - Aztec Code

All Codes Start Setup End Setup ,ZZ, ,ZZ, All Codes Settings: Symbology Exclusive Enable Disable All 1D Codes (default

Strany 36 - Aztec Runes

Number of Characters Start Setup End Setup ,ZZ, ,ZZ, Number of Characters Settings: If you are going to read bar codes

Strany 37 - Data Matrix

Composite Codes Start Setup End Setup ,ZZ, ,ZZ, Composite Codes Settings: Link Flag not ignore link flag for RSS/EAN-12

Strany 38 - Codablock F

String Options Start Setup End Setup ,ZZ, ,ZZ, Case Conversion Settings: Case Conversion no case conversion (AbCd ->

Strany 39 - Chinese Sensible Code

Prefix / Suffix Commands: Symbology Prefix Command Suffix Command All Codes ,RY, ,RZ, UPC-A ,N1, ,N6, UPC-A add-on ,M0, ,O0, UPC-E ,N2, ,N7, UPC-E add

Strany 40 - All Codes

Prefix / Suffix Commands Continued: Symbology Prefix Command Suffix Command POSTNET ,D6D, ,D6E, GS1 DataBar ,OE, ,PQ, Composite code ,RR, ,RS, Codablo

Strany 41 - Number of Characters

Prefix / Suffix ASCII Value Table: ASCII Command ASCII Command ASCII Command ASCII Command <SP> ,5A, A ,0A, a ,$A, (NULL) ,9G, ! ,5B, B ,0B, b ,

Strany 42 - Composite Codes

Prefix / Suffix ASCII Value Table Continued: ASCII Command ASCII Command ASCII Command ASCII Command ^ ,7D, 0 ,Q0, (SUB) ,1Z, _ ,7E, 1 ,Q1, (ESC)

Strany 43 - String Options

Worth Data Code ID Prefix / Suffix Values: Code Code ID Code Code ID UPC-A C MSI/Plessey Z UPC-A +2 F Telepen d UPC-A +5 G UK/Plessey a UPC-E D Code 1

Strany 44 - Suffix Command

Collective Reading Start Setup End Setup ,ZZ, ,ZZ, Collective Reading Settings: It is possible to not output data unles

Strany 45

Chapter 1 Installation Components of 520-2D Reader In the event the shipping box shows damage on arrival, please note the damage on the carrier'

Strany 46

Collective Reading Settings Continued: Same Label Read disable same label read during multiple read default ,D0T, enable same label read during multip

Strany 47

Read Mode Start Setup End Setup ,ZZ, ,ZZ, Read Mode Settings: Read Mode single read default ,S0, multiple read (see bel

Strany 48 - Code ID

Read Mode Settings Continued: Auto Trigger (Stand Mode) enable auto trigger ,+I, disable auto trigger default ,+F, Auto Trigger Synchronization disa

Strany 49 - Collective Reading

Read Mode Settings Continued: Normal Read Time read time 0 second ,Y0, read time 1 second ,Y1, read time 2 seconds default ,Y2, read time 3 seconds

Strany 50

Read Mode Settings Continued: Add-on Delay Timer disable add-on wait more default ,XA, add-on wait mode = 0.25 seconds ,XB, add-on wait mode = 0.50 s

Strany 51 - Read Mode

Imager Settings: Illumination Mode disable LED illumination ,D3A, enable LED illumination default ,D39, LED illumination alternating ,D3B, Aiming O

Strany 52

Indicator Settings Start Setup End Setup ,ZZ, ,ZZ, Buzzer enable good read buzzer default ,W8, disable good read buzze

Strany 53

USB Keyboard Country Start Setup End Setup ,ZZ, ,ZZ, USB Keyboard Country Codes: Country Command USA default ,KE, UK

Strany 54

Diagnostics Start Setup End Setup ,ZZ, ,ZZ, Diagnostic Codes: Diagnostics Transmit software version ,Z1, Transmit setti

Strany 55 - Imager Settings:

Appendix B Resolving USB Installation Issues The USB HID (Human Interface Device) keyboard driver is standard with Windows®. Most recent versions of

Strany 56 - Indicator Settings

Chapter 2 Configuration Configuration of the 520-2D Reader The 520-2D is configured using the setup bar codes found in Appendix A. Most commands are

Strany 57 - USB Keyboard Country

Windows 7 & Vista: 1. Go to the Start menu. 2. Select Control Panel. 3. Switch to Classic View if you are in Category View 4. Select System. 5. Se

Strany 58 - Diagnostics

Appendix A Setup Codes 1D Codes: Code Type Enabled by Default Additional Setup Info UPC yes page A-4 EAN yes page A-5 EAN-13 yes page A-5 EAN-8 yes

Strany 59

2D codes: Code Type Enabled by Default Additional Setup Info PDF417 yes page A-24 Micro PDF417 yes page A-25 Maxi Code yes page A-26 QR Code yes pa

Strany 60 - Windows 7 & Vista:

Set to factory default: To set the scanner to factory defaults, scan one of the codes below. Set USB I/F and Reset All Settings to Default